Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.564
Filtrar
1.
Biomed Microdevices ; 26(2): 21, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558326

RESUMO

Kirigami is one of the interesting paper art forms and the modified sub-class of origami. Kirigami paper art is widely employed in a variety of applications, and it is currently being used in biosensors because of its outstanding advantages. This is the first study on the use of a Kirigami-based aptasensor for DENV (Dengue virus)-antigen detection. In this study, the kirigami approach has been utilized to develop a stretchable, movable, and flexible sensor. The constructed stretchable-kirigami electrode helps in adjusting the connection of electrodes without disturbing the electrochemical cell zone during the experiment. To increase the sensitivity of this biosensor we have synthesized Ag-NPs (Silver nanoparticles) via chemical methods and characterized their results with the help of TEM & UV-Vis Spectroscopy. Different electrochemical approaches were used to validate the sensor response i.e., CV (Cyclic voltammetry) and LSV (Linear sweep voltammetry), which exhibited great detection capability towards dengue virus with the range of 0.1 µg/ml to 1000 µg/ml along with a detection limit of 0.1 µg/ml and showing no reactivity to the chikungunya virus antigen, making it more specific to the DENV antigen. Serum (healthy-human) was also successfully applied to validate the results of the constructed aptasensor. Integration of the Kirigami approach form with the electrochemical aptasensor that utilizes a 3-E setup (three-electrode setup) which is referred to as a tripod and collectively called Kirigami-tripod-based aptasensor. Thus, the developed integrated platform improves the sensors capabilities in terms of cost efficiency, high stretchability, and sensitivity.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Dengue , Nanopartículas Metálicas , Humanos , Nanopartículas Metálicas/química , Técnicas Eletroquímicas/métodos , Aptâmeros de Nucleotídeos/química , Ouro/química , Prata/química , Técnicas Biossensoriais/métodos , Eletrodos , Dengue/diagnóstico , Limite de Detecção
2.
Euro Surveill ; 29(14)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38577804

RESUMO

In February 2023, German public health authorities reported two dengue cases (one confirmed, one probable) and four possible cases who travelled to Ibiza, Spain, in late summer/autumn 2022; the infection was probably acquired through mosquito bites. Case 1 visited Ibiza over 1 week in late August with two familial companions; all three developed symptoms the day after returning home. Only Case 1 was tested; dengue virus (DENV) infection was confirmed by presence of NS1 antigen and IgM antibodies. Case 2 travelled to Ibiza with two familial companions for 1 week in early October, and stayed in the same town as Case 1. Case 2 showed symptoms on the day of return, and the familial companions 1 day before and 3 days after return; Case 2 tested positive for DENV IgM. The most probable source case had symptom onset in mid-August, and travelled to a dengue-endemic country prior to a stay in the same municipality of Ibiza for 20 days, until the end of August. Dengue diagnosis was probable based on positive DENV IgM. Aedes albopictus, a competent vector for dengue, has been present in Ibiza since 2014. This is the first report of a local dengue transmission event on Ibiza.


Assuntos
Aedes , Vírus da Dengue , Dengue , Animais , Humanos , Dengue/diagnóstico , Dengue/epidemiologia , Vírus da Dengue/genética , Espanha/epidemiologia , Mosquitos Vetores , Surtos de Doenças , Imunoglobulina M
3.
Rom J Ophthalmol ; 68(1): 31-36, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38617719

RESUMO

Purpose: To report patients who first presented with various ocular manifestations and eventually ascertained to have underlying dengue. Methods: A prospective study was conducted at multiple tertiary eye-care centers in India from 2012 to 2022. Cases reporting initially with ocular features along with fever/past history of fever over the last two weeks or with clinical features of dengue were selected. After an ophthalmological examination, patients underwent complete serological and biochemical analysis and those with reduced platelet counts were evaluated for dengue. Results: Out of 564 cases, 15 patients were verified to be afflicted with dengue eventually. A rising trend of cases was seen every year and out of 15 cases, eight cases were reported during the Covid-19 pandemic (from 2020 to 2022), but were COVID-negative. 9 cases presented with acute redness followed by diminished vision. Seven cases presented a history of fever over the last few days and one had traveled from dengue endemic area. The various ocular presentations included subconjunctival hemorrhage, viral keratitis, anterior uveitis, sixth-nerve palsy, and vitreous hemorrhage. On serological examination, all 15 patients were detected to have low platelets. All cases responded well with supportive treatment and the ocular features subsided in all within a couple of weeks with good visual recovery. Conclusion: In a tropical nation, such as India, with endemic dengue zones and increasing figures of dengue lately, ophthalmologists must include dengue fever among the differential diagnoses in various ocular presentations like subconjunctival hemorrhage, viral keratitis, anterior uveitis, sixth nerve palsy, and vitreous hemorrhage. Abbreviations: DHF = dengue hemorrhagic fever, PCR = polymerase chain reaction, RT-PCR = real-time automated reverse transcriptase (RT-PCR), SD = standard deviation, MAC-ELIS = IgM antibodies capture enzyme-linked immunosorbent assay, RE = right eye, LE = left eye, CECT = Contrast-enhanced computed tomography.


Assuntos
Doenças do Nervo Abducente , Dengue , Infecções Oculares Virais , Ceratite , Uveíte Anterior , Humanos , Hemorragia Vítrea , Pandemias , Estudos Prospectivos , Infecções Oculares Virais/diagnóstico , Infecções Oculares Virais/epidemiologia , Dengue/complicações , Dengue/diagnóstico , Dengue/epidemiologia
4.
PLoS One ; 19(4): e0301644, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38573991

RESUMO

Dengue and chikungunya are co-circulating vector-borne diseases that share a significant number of clinical symptoms. To identify variables to aid physicians in making rapid and effective diagnostic decisions, we performed molecular diagnosis of the chikungunya virus and examined the clinical manifestations of chikungunya cases to identify the prevalence among dengue-negative individuals in Kolkata. Dengue suspected patients' samples were collected during January 2020-December 2021 and Enzyme-linked immunosorbent assay (ELISA) and reverse transcription-polymerase chain reaction (RT-PCR) methods have been performed to confirm the prevalence of chikungunya infection among dengue-negative patients. By performing phylogenetic analysis, comparing clinical classifications, identifying disease aetiology using clinical and laboratory factors, and evaluating the time course of several clinical variables, we have evaluated the clinical manifestations linked to dengue and chikungunya virus infections. Chikungunya infection was found in 15.1% and 6.3% of the 635 dengue-negative patients, as determined by ELISA and RT-PCR, respectively. Arthritis and myalgia were more common in chikungunya-infected patients at the time of hospital admission while conjunctivitis, photosensitivity, arthralgia, Anorexia, fatigue, retro-orbital pain, vomiting, dermatitis, or swollen glands were significantly presented as an overlapping symptom. Although dengue and chikungunya infections have significant clinical overlap, basic clinical and laboratory criteria can predict these diseases at presentation for proper management. Effective management enables doctors to treat and care for patients properly and contributes to the development of control measures for these infections in a medical setting.


Assuntos
Febre de Chikungunya , Vírus Chikungunya , Dengue , Humanos , Febre de Chikungunya/diagnóstico , Febre de Chikungunya/epidemiologia , Filogenia , Dengue/diagnóstico , Dengue/epidemiologia , Anticorpos Antivirais , Índia/epidemiologia
5.
Arch. argent. pediatr ; 122(2): e202310144, abr. 2024. tab, ilus
Artigo em Inglês, Espanhol | LILACS, BINACIS | ID: biblio-1537966

RESUMO

El dengue es una enfermedad viral transmitida por la picadura del mosquito Aedes aegypti. El comportamiento del dengue en Argentina es epidémico; la mayoría de los casos se observan en los meses de mayor temperatura. Hasta la semana epidemiológica (SE) 20/2023, se registraron en Argentina 106 672 casos; se vieron afectadas 18 de las 24 provincias que conforman el país. Dentro de los principales grupos de riesgo, se incluyen los menores de 2 años. Reconocer los signos, síntomas e identificar los factores de riesgo es fundamental para el manejo de casos con mayor riesgo de gravedad. Presentamos el caso de una paciente de 32 días de vida que se internó por síndrome febril sin foco, con diagnósticos diferenciales de meningitis viral y sepsis, evolucionó con leucocitosis, plaquetopenia, hipoalbuminemia, asociado a exantema y edemas. Se llegó al diagnóstico de dengue por la clínica, epidemiologia e IgM positiva.


Dengue fever is a viral disease transmitted by the Aedes aegypti mosquitoes. In Argentina, dengue fever is an epidemic disease; most cases are reported during the hot months.Until epidemiological week (EW) 20/2023, 106 672 cases were reported across 18 of the 24 provinces of Argentina. Children younger than 2 years are among the main groups at risk. Recognizing signs and symptoms and identifying risk factors is fundamental for the management of cases at a higher risk of severity. Here we describe the case of a 32-day-old female patient who was hospitalized due to febrile syndrome without a source, who had a differential diagnosis of viral meningitis and sepsis and progressed to leukocytosis, thrombocytopenia, hypoalbuminemia in association with rash and edema. The diagnosis of dengue fever was established based on clinical, epidemiological, and positive IgM data.


Assuntos
Humanos , Animais , Feminino , Lactente , Aedes , Dengue/complicações , Dengue/diagnóstico , Dengue/epidemiologia , Argentina , Fatores de Risco , Diagnóstico Diferencial
6.
PLoS Negl Trop Dis ; 18(3): e0012013, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38484018

RESUMO

BACKGROUND: Chikungunya virus (CHIKV) has spread across Brazil with varying incidence rates depending on the affected areas. Due to cocirculation of arboviruses and overlapping disease symptoms, CHIKV infection may be underdiagnosed. To understand the lack of CHIKV epidemics in São José do Rio Preto (SJdRP), São Paulo (SP), Brazil, we evaluated viral circulation by investigating anti-CHIKV IgG seroconversion in a prospective study of asymptomatic individuals and detecting anti-CHIKV IgM in individuals suspected of dengue infection, as well as CHIKV presence in Aedes mosquitoes. The opportunity to assess two different groups (symptomatic and asymptomatic) exposed at the same geographic region aimed to broaden the possibility of identifying the viral circulation, which had been previously considered absent. METHODOLOGY/PRINCIPAL FINDINGS: Based on a prospective population study model and demographic characteristics (sex and age), we analyzed the anti-CHIKV IgG seroconversion rate in 341 subjects by ELISA over four years. The seroprevalence increased from 0.35% in the first year to 2.3% after 3 years of follow-up. Additionally, we investigated 497 samples from a blood panel collected from dengue-suspected individuals during the 2019 dengue outbreak in SJdRP. In total, 4.4% were positive for anti-CHIKV IgM, and 8.6% were positive for IgG. To exclude alphavirus cross-reactivity, we evaluated the presence of anti-Mayaro virus (MAYV) IgG by ELISA, and the positivity rate was 0.3% in the population study and 0.8% in the blood panel samples. In CHIKV and MAYV plaque reduction neutralization tests (PRNTs), the positivity rate for CHIKV-neutralizing antibodies in these ELISA-positive samples was 46.7%, while no MAYV-neutralizing antibodies were detected. Genomic sequencing and phylogenetic analysis revealed CHIKV genotype ECSA in São José do Rio Preto, SP. Finally, mosquitoes collected to complement human surveillance revealed CHIKV positivity of 2.76% of A. aegypti and 9.09% of A. albopictus (although it was far less abundant than A. aegypti) by RT-qPCR. CONCLUSIONS/SIGNIFICANCE: Our data suggest cryptic CHIKV circulation in SJdRP detected by continual active surveillance. These low levels, but increasing, of viral circulation highlight the possibility of CHIKV outbreaks, as there is a large naïve population. Improved knowledge of the epidemiological situation might aid in outbreaks prevention.


Assuntos
Aedes , Febre de Chikungunya , Vírus Chikungunya , Dengue , Animais , Humanos , Vírus Chikungunya/genética , Estudos Prospectivos , Brasil/epidemiologia , Filogenia , Estudos Soroepidemiológicos , Febre de Chikungunya/epidemiologia , Anticorpos Antivirais , Dengue/diagnóstico , Dengue/epidemiologia , Anticorpos Neutralizantes/genética , Imunoglobulina G , Imunoglobulina M
7.
Biosens Bioelectron ; 254: 116218, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38518559

RESUMO

Biodetection for non-invasive diagnostics of fluids, especially urine, remains a challenge to scientists due to low target concentrations. And biological complexes of the detection target may contain contaminants that also interfere with any assay. Dengue non-structural 1 protein (Dengue NS1) is an important biomarker for dengue hemorrhagic fever and dengue shock syndrome. Here, we developed an Au-decorated nanowire platform and applied it with a sandwich fluorophore-linked immunosorbent well plate assay (FLISA) to detect Dengue NS1 in urine. For the platform, we fabricated zinc oxide (ZnO) nanowires to provide a high surface area and then coated them with gold nanoparticles (ZnO/Au nanowires) to simply modify the Dengue NS1 antibody and enhance the fluorescence intensity. Our platform employs a sandwich FLISA that exhibits high sensitivity, specifically detecting Dengue NS1 with a limit of detection (LOD) of 1.35 pg/mL. This LOD was 4500-fold lower than the LOD of a commercially available kit for Dengue NS1 enzyme-linked immunosorbent assay. We believe that our ZnO/Au nanowire platform has the potential to revolutionize the field of non-invasive diagnostics for dengue.


Assuntos
Técnicas Biossensoriais , Vírus da Dengue , Dengue , Nanopartículas Metálicas , Nanofios , Óxido de Zinco , Humanos , Dengue/diagnóstico , Ouro , Sensibilidade e Especificidade , Proteínas não Estruturais Virais , Antígenos Virais , Ensaio de Imunoadsorção Enzimática , Imunoadsorventes , Anticorpos Antivirais
8.
J Investig Med High Impact Case Rep ; 12: 23247096241242574, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38546109

RESUMO

Stevens-Johnson syndrome is an infrequent condition affecting the skin and mucous membranes, it involves cutaneous detachment with high mortality without adequate treatment. We present the case of a 40-year-old male with a history of epilepsy treated with valproic acid and lamotrigine, previously diagnosed with dengue. Evaluation showed erythematous blisters on skin and mucosa with bleeding and desquamation, covering 10% of the body surface. The patient progressed favorably with the medical care received. Stevens-Johnson syndrome should be studied in association with arboviral diseases.


Assuntos
Dengue , Síndrome de Stevens-Johnson , Masculino , Humanos , Adulto , Síndrome de Stevens-Johnson/complicações , Síndrome de Stevens-Johnson/diagnóstico , Peru , Anticonvulsivantes , Ácido Valproico/uso terapêutico , Dengue/complicações , Dengue/diagnóstico
9.
ACS Appl Bio Mater ; 7(4): 2299-2308, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38476032

RESUMO

Smartphones' widespread availability and worldwide connection are advancing the idea of mobile-based healthcare and promise to transform the business of biosensors. Biosensors based on smartphones have been investigated in several ways, including employing a smartphone in place of a detector or as an instrumental interface. The current work demonstrates the first successful detection of dengue virus using a smartphone-based pocket sensor combined with a wireless potentiostat. The platform developed comprises a smartphone, a wireless portable potentiostat, an Android app, and a three-electrode setup. The combination of portable diagnostic with electronic application is referred to as "Portronicx", and this is the first time that the term "Portronicx" has been used in a dengue sensor, so the current study has the potential to be commercialized in the market with the tag line "Portronicx-commercialization" in the future. Miniaturization improves alternative setup options in terms of instrument size, affordability, mobility, touch-mobile display, and design versatility. The current work proved the excellent combination of a wireless potentiostat with an aptasensor to detect dengue antigen within 20 s with good LOD (0.1 µg/mL) and easy to carry in their pockets. The created platform also performed effectively in human serum. This study replaced all of the instruments with a lightweight touch smartphone, paving the way for the production of fifth-generation electrochemical aptasensors, with potential implications for healthcare applications on the verge of commercialization.


Assuntos
Técnicas Biossensoriais , Dengue , Humanos , Smartphone , Eletrodos , Dengue/diagnóstico
10.
Am J Trop Med Hyg ; 110(4): 738-740, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38471167

RESUMO

Asymptomatic dengue virus (DENV) infections have important public health implications but are challenging to identify. We performed a cross-sectional study of reverse transcription quantitative polymerase chain reaction on pooled sera of asymptomatic individuals from the south coast of Kenya at two time periods to identify cases of asymptomatic viremia. Among 2,460 samples tested in pools of 9 or 10, we found only one positive case (0.04% incidence). Although pooling of samples has the potential to be a cost-effective and time-efficient method for asymptomatic DENV detection, mass cross-sectional pooled testing may not provide accurate data on rates of asymptomatic infection, likely owing to a decrease in the sensitivity with pooling of samples, a short period of viremia, or testing in the absence of an outbreak.


Assuntos
Vírus da Dengue , Dengue , Humanos , Vírus da Dengue/genética , Dengue/diagnóstico , Dengue/epidemiologia , Estudos Transversais , Infecções Assintomáticas/epidemiologia , Quênia/epidemiologia , Viremia , Reação em Cadeia da Polimerase
11.
Mikrochim Acta ; 191(4): 174, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436801

RESUMO

Early diagnosis of dengue infection by detecting the dengue virus non-structural protein 1 (DENV-NS1) is important to the patients to initiate speedy treatment. Enzyme-linked immunosorbent assay (ELISA)-based NS1 detection and RT-PCR are time-consuming and too complex to be employed in remote areas of dengue-endemic countries. Meanwhile, those of NS1 rapid test by lateral flow assay suffer from low detection limit. Electrochemical-based biosensors using screen-printed gold electrodes (SPGEs) have become a reliable detection method to convey both ELISA's high sensitivity and rapid test portability. In this research, we developed an electrochemical biosensor for DENV-NS1 detection by employing polydopamine (PDA)-modified SPGE. The electrodeposition of PDA on the surface of SPGE serves as a bioconjugation avenue for anti-NS1 antibody through a simple and low-cost immobilization procedure. The biosensor performance was evaluated to detect DENV-NS1 protein in PBS and human serum through a differential pulse voltammetric (DPV) technique. The developed sensing platform displayed a low limit of detection (LOD) of 1.63 pg mL-1 and a wide linear range of 10 pg mL-1 to 1 ng mL-1 (R2 ∼ 0.969). The sensing platform also detected DEV-NS1 from four different serotypes in the clinical samples collected from dengue patients in India and Indonesia, with acceptable sensitivity, specificity, and accuracy values of 90.00%, 80.95%, and 87.65%, respectively. This result showcased the facile and versatile method of PDA coating onto the surface of screen-printed gold electrodes for a miniaturized point-of-care (PoC) detection device.


Assuntos
Vírus da Dengue , Dengue , Indóis , Sistemas Automatizados de Assistência Junto ao Leito , Polímeros , Humanos , Dengue/diagnóstico , Eletrodos , Ouro , Proteínas não Estruturais Virais/química
12.
BMC Infect Dis ; 24(1): 319, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491361

RESUMO

BACKGROUND: Dengue is an important public health problem, which caused by the dengue virus (DENV), a single-stranded RNA virus consisted of four serotypes. Central nervus system (CNS) impairment in dengue usually results from DENV-2 or DENV-3 infection, which lead to life-threatening outcomes. Furthermore, neurological complications due to DENV-1 was rare especially in adult patients. CASE PRESENTATION: A 44-year-old man without comorbidities had lethargy after hyperpyrexia and a positive DENV NS1 antigen was detected for confirming the diagnosis of dengue on day 8 of onset. Then logagnosia, decreased muscle strength, delirium and irritability were occurred even radiographic examination were normal. He was treated with low-dose hormone, sedatives and gamma goblin with a short duration of 6 days. The cerebrospinal fluid (CSF) tests were persistent normal. However, presence of DENV-1 RNA was confirmed both in CSF and serum. Furthermore, the complete sequence of the DENV isolated from the patient's serum was performed (GenBank No.: MW261838). The cytokines as IL-6, IL-10 and sVCAM-1 were increased in critical phase of disease. Finally, the patient was discharged on day 24 of onset without any neurological sequelae. CONCLUSION: Encephalopathy caused by a direct CNS invasion due to DENV-1 during viremia was described in an adult patient. Treatment with low-dose hormone and gamma goblin was helpful for admission.


Assuntos
Encefalopatias , Vírus da Dengue , Dengue , Adulto , Masculino , Humanos , Dengue/complicações , Dengue/diagnóstico , Sorogrupo , Hormônios , Anticorpos Antivirais
14.
Viruses ; 16(2)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38399957

RESUMO

In 2019-2020, dengue virus (DENV) type 4 emerged to cause the largest DENV outbreak in Paraguay's history. This study sought to characterize dengue relative to other acute illness cases and use phylogenetic analysis to understand the outbreak's origin. Individuals with an acute illness (≤7 days) were enrolled and tested for DENV nonstructural protein 1 (NS1) and viral RNA by real-time RT-PCR. Near-complete genome sequences were obtained from 62 DENV-4 positive samples. From January 2019 to March 2020, 799 participants were enrolled: 253 dengue (14 severe dengue, 5.5%) and 546 other acute illness cases. DENV-4 was detected in 238 dengue cases (94.1%). NS1 detection by rapid test was 52.5% sensitive (53/101) and 96.5% specific (387/401) for dengue compared to rRT-PCR. DENV-4 sequences were grouped into two clades within genotype II. No clustering was observed based on dengue severity, location, or date. Sequences obtained here were most closely related to 2018 DENV-4 sequences from Paraguay, followed by a 2013 sequence from southern Brazil. DENV-4 can result in large outbreaks, including severe cases, and is poorly detected with available rapid diagnostics. Outbreak strains seem to have been circulating in Paraguay and Brazil prior to 2018, highlighting the importance of sustained DENV genomic surveillance.


Assuntos
Vírus da Dengue , Dengue , Humanos , Vírus da Dengue/genética , Dengue/diagnóstico , Dengue/epidemiologia , Paraguai/epidemiologia , Filogenia , Doença Aguda , Genótipo , Surtos de Doenças
15.
Eur J Immunol ; 54(4): e2350784, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38308504

RESUMO

Fever is common among individuals seeking healthcare after traveling to tropical regions. Despite the association with potentially severe disease, the etiology is often not determined. Plasma protein patterns can be informative to understand the host response to infection and can potentially indicate the pathogen causing the disease. In this study, we measured 49 proteins in the plasma of 124 patients with fever after travel to tropical or subtropical regions. The patients had confirmed diagnoses of either malaria, dengue fever, influenza, bacterial respiratory tract infection, or bacterial gastroenteritis, representing the most common etiologies. We used multivariate and machine learning methods to identify combinations of proteins that contributed to distinguishing infected patients from healthy controls, and each other. Malaria displayed the most unique protein signature, indicating a strong immunoregulatory response with high levels of IL10, sTNFRI and II, and sCD25 but low levels of sCD40L. In contrast, bacterial gastroenteritis had high levels of sCD40L, APRIL, and IFN-γ, while dengue was the only infection with elevated IFN-α2. These results suggest that characterization of the inflammatory profile of individuals with fever can help to identify disease-specific host responses, which in turn can be used to guide future research on diagnostic strategies and therapeutic interventions.


Assuntos
Infecções Bacterianas , Dengue , Gastroenterite , Malária , Infecções Respiratórias , Humanos , Dengue/diagnóstico , Infecções Respiratórias/complicações , Gastroenterite/complicações , Viagem , Febre/complicações
16.
Diagn Microbiol Infect Dis ; 109(1): 116204, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38402756

RESUMO

This study aims to determine the frequency and clinical manifestations of dengue and chikungunya viral infections in the district hospital of Mfou, Centre region of Cameroon where malaria is endemic. Blood samples were collected from suspected cases and tested for Plasmodium parasites and for the molecular detection of viral RNAs (dengue, zika and chikungunya viruses) using TRIOPLEX qPCR. A total of 108 patients were clinically suspected among which 25 % were male and 50 % were less than 15.5 years old. Of these 14.8 % (16/108) and 2.8 % (3/108) had acute dengue and chikungunya fevers respectively. Co-infection with malaria was reported in 56.3 % (9/16) of Dengue cases and 33.3 % (1/3) of chikungunya cases. Clinical profiling further revealed that nausea and vomiting show a significant difference in dengue infected individuals to those of non-infected individuals (P = 0.027). The presence of dengue fever and chikungunya fever and the absence of specific clinical manifestations highlight the need to strengthen surveillance of acute febrile infections for a better estimation of the burden of arboviruses.


Assuntos
Febre de Chikungunya , Vírus Chikungunya , Vírus da Dengue , Dengue , Malária , Infecção por Zika virus , Zika virus , Humanos , Masculino , Adolescente , Feminino , Febre de Chikungunya/complicações , Febre de Chikungunya/epidemiologia , Febre de Chikungunya/diagnóstico , Dengue/complicações , Dengue/epidemiologia , Dengue/diagnóstico , Vírus da Dengue/genética , Camarões/epidemiologia , Vírus Chikungunya/genética , Infecção por Zika virus/diagnóstico , Malária/complicações , Malária/epidemiologia , Febre/epidemiologia
17.
Sensors (Basel) ; 24(3)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38339518

RESUMO

There is currently a lot of interest in the construction of point-of-care devices stemming from paper-based origami biosensors. These devices demonstrate how paper's foldability permits the construction of sensitive, selective, user-friendly, intelligent, and maintainable analytical devices for the detection of several ailments. Herein, the first example of the electrochemical aptasensor-based polyvalent dengue viral antigen detection using the origami paper-folding method is presented. Coupling it with an aptamer leads to the development of a new notation known as OBAs, or origami-based aptasensor, that presents a multitude of advantages to the developed platform, such as assisting in safeguarding the sample from air-dust particles, providing confidentiality, and providing a closed chamber to the electrodes. In this paper, gold-decorated nanocomposites of zinc and graphene oxide (Au/ZnO/GO) were synthesized via the chemical method, and characterization was conducted by Scanning Electron Microscope, Transmission Electron Microscope, UV-Vis, and XRD which reveals the successful formation of nanocomposites, mainly helping to enhance the signal and specificity of the sensor by employing aptamers, since isolation and purification procedures are not required. The biosensor that is being demonstrated here is affordable, simple, and efficient. The reported biosensor is an OBA detection of polyvalent antigens of the dengue virus in human serum, presenting a good range from 0.0001 to 0.1 mg/mL with a limit of detection of 0.0001 mg/mL. The reported single-folding ori-aptasensor demonstrates exceptional sensitivity, specificity, and performance in human serum assays, and can also be used for the POC testing of various viral infections in remote areas and underdeveloped countries, as well as being potentially effective during outbreaks. Highlights: (1) First report on origami-based aptasensors for the detection of polyvalent antigens of DENV; (2) In-house construction of low-cost origami-based setup; (3) Gold-decorated zinc/graphene nanocomposite characterization was confirmed via FESEM/UV-Vis/FTIR; (4) Cross-reactivity of dengue-aptamer has been deduced; (5) Electrochemical validation was conducted through CV.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Vírus da Dengue , Dengue , Grafite , Nanocompostos , Humanos , Técnicas Eletroquímicas/métodos , Grafite/química , Nanocompostos/química , Técnicas Biossensoriais/métodos , Dengue/diagnóstico , Ouro/química , Zinco , Aptâmeros de Nucleotídeos/química , Limite de Detecção
18.
Rev Med Virol ; 34(2): e2521, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38340071

RESUMO

Dengue, Zika and chikungunya outbreaks pose a significant public health risk to Pacific Island communities. Differential diagnosis is challenging due to overlapping clinical features and limited availability of laboratory diagnostic facilities. There is also insufficient information regarding the complications of these arboviruses, particularly for Zika and chikungunya. We conducted a systematic review and meta-analysis to calculate pooled prevalence estimates with 95% confidence intervals (CI) for the clinical manifestations of dengue, Zika and chikungunya in the Pacific Islands. Based on pooled prevalence estimates, clinical features that may help to differentiate between the arboviruses include headache, haemorrhage and hepatomegaly in dengue; rash, conjunctivitis and peripheral oedema in Zika; and the combination of fever and arthralgia in chikungunya infections. We estimated that the hospitalisation and mortality rates in dengue were 9.90% (95% CI 7.67-12.37) and 0.23% (95% CI 0.16-0.31), respectively. Severe forms of dengue occurred in 1.92% (95% CI 0.72-3.63) of reported cases and 23.23% (95% CI 13.58-34.53) of hospitalised patients. Complications associated with Zika virus included Guillain-Barré syndrome (GBS), estimated to occur in 14.08 (95% CI 11.71-16.66) per 10,000 reported cases, and congenital brain malformations such as microcephaly, particularly with first trimester maternal infection. For chikungunya, the hospitalisation rate was 2.57% (95% CI 1.30-4.25) and the risk of GBS was estimated at 1.70 (95% CI 1.06-2.48) per 10,000 reported cases. Whilst ongoing research is required, this systematic review enhances existing knowledge on the clinical manifestations of dengue, Zika and chikungunya infections and will assist Pacific Island clinicians during future arbovirus outbreaks.


Assuntos
Arbovírus , Febre de Chikungunya , Dengue , Infecção por Zika virus , Zika virus , Humanos , Febre de Chikungunya/complicações , Febre de Chikungunya/diagnóstico , Febre de Chikungunya/epidemiologia , Ilhas do Pacífico/epidemiologia , Dengue/complicações , Dengue/diagnóstico , Dengue/epidemiologia , Infecção por Zika virus/complicações , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/epidemiologia
20.
J Coll Physicians Surg Pak ; 34(2): 241-243, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38342881

RESUMO

The study aimed to determine if deranged liver function tests (LFTs) can predict severe dengue or mortality. It included 135 dengue patients, with a mean age of 30.9 ± 12.09 years. Among the patients, 82 (60.7%) were under 30 years of age. Nearly half of the patients (64, 47. 4%) had some degree of liver damage indicated by deranged LFTs, 27 (42.1%) had elevated alanine transaminase (ALT), 7 (10.9%) had increased bilirubin, and 30 (46.9%) had high values of alkaline phosphatase (ALP). However, only elevated ALP levels were positively correlated with mortality (Pearson's R = 0.282, p = <0.05). The mean bilirubin was 11.711 ± 8.602 umol/l, and the mean values of ALT and ALP were 107 ± 240 and 113.571 ± 59.91 IU/L, respectively, which were higher than the normal. The study findings suggested that hepatic derangement is a common occurrence in dengue patients, and increased ALP levels could be an indicator of a higher risk of mortality. These findings can help improve patient care by identifying the potential risk factors for mortality. Key Words: Dengue, Liver function tests, Alanine transaminase, Alkaline phosphatase.


Assuntos
Dengue , Dengue Grave , Humanos , Adolescente , Adulto Jovem , Adulto , Dengue Grave/complicações , Dengue Grave/diagnóstico , Fosfatase Alcalina , Alanina Transaminase , Fígado , Testes de Função Hepática , Bilirrubina , Aspartato Aminotransferases , Dengue/complicações , Dengue/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...